1. Home
  2. Resources
  3. Acrylic sheet thickness: how to choose without over-specifying
Buyer guide

Acrylic sheet thickness: how to choose without over-specifying

Almost every acrylic quotation we correct starts the same way: the buyer specified a thickness from a photograph, not from a load. Over-specifying doubles the material cost and the freight; under-specifying produces a panel that bows in service. This guide gives you the working ranges we use, and the reasoning behind them.

The selection table

ApplicationTypical thicknessWhat drives the choice
Signage, light covers, small risers2–3 mmSpan under 300 mm, no load. Extruded sheet is usually adequate.
Counter-top display risers, step stands4–6 mmSelf-supporting over 300–500 mm; edge appearance starts to matter.
Five-sided vitrines, jewellery cases6–10 mmBonded joints need wall thickness to hold a clean seam.
Retail display cases with doors10–15 mmHinge and lock loads concentrate at the panel edge.
Hotel reception and bar counters20–100 mmVisual depth plus edge glow; thick sections must be annealed.
Aquarium viewing, up to 3 m head60–150 mmWater pressure and unsupported span — always calculated.
Public aquarium tunnel, 8 m head250–400 mmPressure plus safety factor plus optical path length.

Three cases where thicker is worse

1. Bonded joints on extruded sheet. Going up in thickness on extruded acrylic does not fix a crazing joint — it delays it. The material, not the thickness, is the problem.

2. Freight. Acrylic is sold by volume as often as by weight. A 20 mm counter that could have been 12 mm with a proper sub-frame can cost more to ship than to manufacture.

3. Optical path. Light transmission falls with thickness: roughly 92% at 50 mm, 88% at 300 mm. For a lit counter, a thicker panel can look duller than a thin one unless the lighting is designed for it.

The edge is half the decision

Buyers often specify thickness because they want a thick, premium edge. In practice the finish of that edge does more work than the millimetres do. A 12 mm panel with a diamond-polished, flame-finished edge reads better than a 20 mm panel with a sanded one — and costs far less. If the goal is visual weight, ask for the finish first and the thickness second.

Rule of thumb: choose thickness for load and for the bond, choose finish for appearance, and always check the freight consequence before signing.

When the panel must hold water

Thickness for a pressure panel is not a design preference — it follows from the water head, the unsupported span and the safety factor your engineer sets. Never accept a thickness quoted “from experience” for a panel that holds back water. Ask for the calculation basis; a supplier who cannot produce one has not done the calculation.

Send us your drawings. Get a costed quote within two working days.

Tell us the size, thickness, finish and quantity. We will come back with a manufacturing assessment, a firm unit price range and a realistic lead time — not a sales brochure.