Almost every acrylic quotation we correct starts the same way: the buyer specified a thickness from a photograph, not from a load. Over-specifying doubles the material cost and the freight; under-specifying produces a panel that bows in service. This guide gives you the working ranges we use, and the reasoning behind them.
| Application | Typical thickness | What drives the choice |
|---|---|---|
| Signage, light covers, small risers | 2–3 mm | Span under 300 mm, no load. Extruded sheet is usually adequate. |
| Counter-top display risers, step stands | 4–6 mm | Self-supporting over 300–500 mm; edge appearance starts to matter. |
| Five-sided vitrines, jewellery cases | 6–10 mm | Bonded joints need wall thickness to hold a clean seam. |
| Retail display cases with doors | 10–15 mm | Hinge and lock loads concentrate at the panel edge. |
| Hotel reception and bar counters | 20–100 mm | Visual depth plus edge glow; thick sections must be annealed. |
| Aquarium viewing, up to 3 m head | 60–150 mm | Water pressure and unsupported span — always calculated. |
| Public aquarium tunnel, 8 m head | 250–400 mm | Pressure plus safety factor plus optical path length. |
1. Bonded joints on extruded sheet. Going up in thickness on extruded acrylic does not fix a crazing joint — it delays it. The material, not the thickness, is the problem.
2. Freight. Acrylic is sold by volume as often as by weight. A 20 mm counter that could have been 12 mm with a proper sub-frame can cost more to ship than to manufacture.
3. Optical path. Light transmission falls with thickness: roughly 92% at 50 mm, 88% at 300 mm. For a lit counter, a thicker panel can look duller than a thin one unless the lighting is designed for it.
Buyers often specify thickness because they want a thick, premium edge. In practice the finish of that edge does more work than the millimetres do. A 12 mm panel with a diamond-polished, flame-finished edge reads better than a 20 mm panel with a sanded one — and costs far less. If the goal is visual weight, ask for the finish first and the thickness second.
Rule of thumb: choose thickness for load and for the bond, choose finish for appearance, and always check the freight consequence before signing.
Thickness for a pressure panel is not a design preference — it follows from the water head, the unsupported span and the safety factor your engineer sets. Never accept a thickness quoted “from experience” for a panel that holds back water. Ask for the calculation basis; a supplier who cannot produce one has not done the calculation.
Tell us the size, thickness, finish and quantity. We will come back with a manufacturing assessment, a firm unit price range and a realistic lead time — not a sales brochure.